Perlick TCH: the condenser is running hot, clean the coils

TCH is the G5 alarm for high condenser temperature.

(844) 456-4651

Mon–Sat, 8am–8pm

  • Fans and airflow
  • Freezer evaporator and condenser fan repair
  • Source: Perlick

Book a visit

Three short steps, about a minute.

or call (844) 456-4651

What TCH
actually means.

TCH is the G5 alarm for high condenser temperature. Perlick’s step is to clean the condenser coils as described in the maintenance section, and to book service if the alarm returns within a week.

Perlick freezer display

What to do when TCH shows on the freezer

Before you book,
in this order.

Each step comes from Perlick's own guidance for TCH on its freezers. Follow it to the end: the last card says whether this is a visit.

01

Turn the unit off with the rocker switch or breaker, then clean the condenser coil as the manual describes.

02

Make sure nothing blocks the front grille, where the machinery takes in fresh air.

03

Turn the unit back on and book a visit if TCH repeats within a week.

Still there?

It usually turns into freezer evaporator and condenser fan repair. Book with the code and the model number.

What not to do

TCH is not a failed condenser fan code; that is FCF. It is also not the extra high version, TCX, which Perlick sends straight to service.

What you may
notice with it.

The freezer problems TCH tends to arrive with. Answer these at the freezer before anyone is booked.

All problems

Where TCH usually leads

Freezer evaporator and condenser fan repair.

Evaporator or condenser fan motor · low to moderate.

In Perlick's own words

TCH High Condenser Temperature Clean condenser coils per maintenance instructions.
Perlick G5 User Installation & Operation Manual, Form Z3023 (linked from the G5 Luxe 24-inch freezer drawers page) Perlick G5 User Installation & Operation Manual, Form Z3023 (linked from the G5 Luxe 24-inch freezer drawers page)

Every code on this site is taken from the manufacturer's documentation, never from a forum or a parts listing. Perlick G5 undercounter models with the touch display, including the G5 Luxe 24-inch freezer drawers (URS24E61). The code appears in Alarm History, which keeps the last ten alarms with date and time.

Perlick TCH freezer repair,
where we come out.

The same visit in every metro below: the code, the model number, and a diagnosis before any part is ordered.

All service areas
A parent and a child packing summer berries into bags beside an open upright freezer in a tidy garage
For the heart of your home.

Questions
about TCH.

Can I clear TCH myself?
Turn the unit off with the rocker switch or breaker, then clean the condenser coil as the manual describes. If it comes back, it needs a visit.
How often should I clean the condenser on a Perlick freezer?
Follow the maintenance section of the G5 manual, and clean more often outdoors or near a pool, where dust and debris build up faster.
Can a hot patio cause Perlick TCH?
Yes. A high room temperature raises condenser temperature too. G5 units are rated to a 105°F room.
Does TCH mean my Perlick compressor is failing?
Not usually. Perlick’s first step is cleaning the coils; a compressor problem is only considered if TCH keeps returning.

Back to your everyday

Still showing TCH?

Book with the code or the alarm pattern written exactly as the freezer shows it, the full model number, and whether the food is still frozen hard — when there is a code, that is where the diagnosis starts.

(844) 456-4651 Schedule a repair